The Krebs Radial Manifold System is designed to uniformly distribute the feed and collect the overflow and underflow products from the hydrocyclones as required for the application. System includes feed distributor, overflow and underflow collection launders, and steel support structure.
The hydrocyclones are mounted radially around a central vertical feed header for uniform slurry distribution. Slurry outlet nozzles from the feed header will incorporate a well-rounded entry configuration (as obtainable with "pulled" type nozzles) to minimize slurry turbulence. A pressure gauge with protective diaphragm assembly is mounted to the top of the feed distributor. Flanges for sampling and/or a pressure transmitter can be provided.
To assure uniform feed distribution, the feed chamber has a diameter and cylindrical height above the centerline of the outlet nozzles equal to a minimum of 1-½ times the feed pipe diameter. A domed cover attached by a Victaulic coupling or plate flange is provided to allow access into the feed distributor for inspection and/or maintenance. The feed header and domed cover are constructed with minimum steel plate thickness of ¼" and incorporate a minimum of ¼" vulcanized elastomer lining.
The manifold design permits convenient removal of any hydrocyclone without disturbing other hydrocyclones or disassembling the manifold system. All connecting pipe fittings have standard Victaulic grooved or flanged connections. Blank-off connections are provided for any unused hydrocyclone feed outlet pipes.
An individual isolating valve can be provided for each hydrocyclone as an optional feature. We carefully evaluate the type of valve depending on the application, to ensure it is acceptable for use.
The overflow and underflow launders will be constructed of adequately reinforced steel plate. If elastomer lining is required, it will be a minimum of ¼" thick and be vulcanized to the steel. Launders will be concentric around the central feed pipe and provide efficient collection and transfer of products to discharge lines. The launders are designed to minimize splashing.
The manifold assembly will incorporate the structural steel required to support the radial feed distributor, the hydrocyclones, and the overflow and underflow collection launders.
Assembly support designs are designed per UBC guidelines and are analyzed by a qualified structural engineer for operating and seismic loads.
Each system is assigned an engineering manifold and a file is set up for fabrication drawings, materials, certifications, and if required specific welder qualifications.
All design details of the radial manifold system are confirmed by performing a trial assembly prior to rubber lining. Manifolds are shipped in sections as fully factory assembled as possible. Field assembly will require bolting only; with absolutely no site welding required. All bolts for field assembly and internal connections will be included with shipment. Detailed field assembly drawings and bolts lists are provided. Each manifold is quality checked prior to shipping to ensure all components meet Krebs established standards.